Quick guide, Connect to sensor, Connect to power – AW Gear Meters FEM-03 User Manual
Page 7: Basic key definitions, Programming and data entry, Fem-03 flow monitor
FEM-03 Flow Monitor
Operation and Programming Manual
6
Quick Guide
As with any precision-engineered device, always operate the FEM-03 in accordance with the
manufacturer’s instructions.
Connect to Sensor
You will connect three wires from the sensor to the back of the FEM-03:
a red wire (electrical power)
a white wire (signal), and
a black wire (ground)
Color of wires may vary.
Insert the stripped end of the red wire into upper terminal #1 and use a screwdriver to secure. Insert the
stripped end of the black into upper connection #2 and the stripped end of the white wire into upper
terminal #3. Use a screwdriver to secure these wires.
Connect to Power
Insert the female end of the 110VAC adaptor into the AC 16V input at the back of the FEM-03. Plug the
adaptor into a wall receptacle.
Basic Key Definitions
The FEM-03 has four keys for data input and programming:
DN (down)
UP (up)
SEL (select)
ENT (enter)
Use the SEL key to move the cursor to the digit you would like to change, use the UP and DN keys to
increase or decrease the value as desired, and use the ENT key to enter the information.
Programming and Data Entry
Upon power up, press the UP key to select a display to program. When you reach the display, press and
hold the ENT key. The screen shows a “P” in the lower left corner, and then prompts you to enter a
program variable or numeric entry.
Caution
Notice