Read/Write Variables
Address
Length
Data
Rate A (PL measurement)
0000H
4Bytes
MSB first
Rate A (GT measurement)
0037H
4Bytes
MSB first
Job Total A (READ ONLY)
0004H
4Bytes
MSB first
Grand Total A (READ ONLY)
0020H
4Bytes
MSB first
A-KFR for Rate
0071H
2Bytes
MSB first
A-KFR decimal point location
0075H
1Byte
A-KFT for Total
0073H
2Bytes
MSB first
A-KFT decimal point location
0076H
1Byte
A-Rate Engineering units
0085H
5Bytes
Array last digit 0
A-Total Engineering units
008FH
5Bytes
Array last digit 0
A-Flow Direction
00BEH
1Byte
Rate B (PL measurement)
000EH
4Bytes
MSB first
Rate B (GT measurement)
003BH
4Bytes
MSB first
Job Total B (READ ONLY)
0012H
4Bytes
MSB first
Grand Total B (READ ONLY)
0024H
4Bytes
MSB first
B-KFR for Rate
0077H
2Bytes
MSB first
B-KFR decimal point location
007BH
1Byte
B-Rate Engineering units
008AH
5Bytes
Array last digit 0
B-KFT for Total
0079H
2Bytes
MSB first
B-KFT decimal point location
007CH
1Byte
B-KFT for Total engineering units
0094H
5Bytes
Array last digit 0
Limit 1 Mode
00B3H
1Byte
1=Rate A Gate time
2=Rate A Pulse length
3=Rate B Gate time
4=Rate B Pulse length
5-Totalizer A
6=Totalizer B
Limit 1 (could be Rate or Total)
00B4H
4Bytes
MSB first
Margin 1 for rate limit
00DEH
4Bytes
MSB first
Limit 2 Mode
00B8H
1Byte
1=Rate A Gate time
2=Rate A Pulse length
3=Rate B Gate time
4=Rate B Pulse length
5-Totalizer A
6=Totalizer B
Limit 1 2 could be Rate or Total)
00B9H
4Bytes
MSB first
Margin 2 for rate limit
00E2H
4Bytes
MSB first
Milli-amps Offset
00AFH
4Bytes
MSB first
Milli-amps Out
002BH
4Bytes
MSB first
Analog Out Mode
002AH
1Byte