beautypg.com

Rate a + b, Rate a - b, Tot a - b – AW Gear Meters FEM-03 User Manual

Page 21: Fem-03 flow monitor

background image

FEM-03 Flow Monitor

Operation and Programming Manual

20


RATE A + B/RATE A – B/TOT A – B (FEM-03A2 and -03Ax only, TOTAL A-B as of Rev 1.23
only)

For RATE A+B and RATE A-B, KFR A and KFR B Engineering Units must be the same. The display indicates
NO MATCH if the A and B KFR Engineering Units do not match. For TOTAL A-B and GRTOT A-B, both KFT
A and KFT B Engineering Units and number of decimal places must be the same. The display indicates NO
MATCH if the A and B KFT Engineering Units and number of decimal places do not match.

RATE A + B

PL

Displays the sum RATE A and RATE B (PL or GT). Use SEL to toggle between RATE

PL

and RATE

GT

.

RATE A - B

PL

/TOT A - B

Displays the difference between RATE A and RATE B (PL or GT), TOT A and TOT B, or GRAND TOTAL A
and B. Use SEL to switch from RATE A_B

PL

to RATE A_B

GT

to TOTAL A_B to GRTOT A-B and back.

Notice