Page 20: Fem-03 flow monitor
FEM-03 Flow Monitor
Operation and Programming Manual
19
RATE W/ TOTAL
Use the RATE A_TOT A or RATE B_TOT B displays to view RATE A or B
PL
and TOTAL A or B (Job or Grand).
RATE is based on the pulse length method. Rates and totals are shown in the engineering units based on
the programmed KFR and KFT factors and decimal locations. Use SEL to switch between GR TOTALs,
TOTAL A or B (TA or TB, and GR TOTAL A or B (GA or GB). After a power cycle, the FEM-03 reverts to the
Job Total (TA or TB).
RATE A and B/TOTAL A and B (FEM-03A2 and -03Ax only)
RATE A and B
PL
Displays both RATE A and RATE B determined by the pulse length method and based on the
programmed SAMPLE A/SAMPLE B variables according to the corresponding KFR factors, decimal
locations and engineering units. Press SEL while in RATE A and B
PL
to display RATE A or B
GT
. After a
power cycle, the FEM-03 reverts to RATE A and B
PL
.
TOTAL A and B
Displays JOB or GRAND TOTAL A and TOTAL B based on the programmed KFTs, engineering units, and
decimal locations. The initial display is the JOB totals. Use SEL to switch between the JOB TOTAL A and B
(TA and TB), and GR TOTAL A and B (GA and GB). After a power cycle, the FEM-03 reverts to Job Total
(TA and TB).
(FEM-03A2 and -03Ax only)
(FEM-03A2 and -03Ax only)