beautypg.com

To ups port, Led: table 1, Optional power input – APC SMARTSLOT DP300E User Manual

Page 11: To ups port 5, Led 5, Optional power input 5, Continued, Product description

background image

5

Product Description

continued

To UPS port

The “

To UPS”

port is for connecting the Silcon Triple Chas-

sis unit to the

UPS

, using the Silcon

UPS

cable. The cable

connector plugs into a communications port on a Silcon

DP300E

series

UPS

.

LED:

Table 1

The Silcon Triple Chassis

LED

provides important informa-

tion concerning operation of the unit. Refer to the table
below for a description of the conditions indicated by the

LED

.

Optional Power

input

With the Optional Power input, you can power either model
of the Silcon Triple Chassis from an external source, using a

24 VDC

power adapter. A universal adapter

(AP9505i

) is

supplied with

AP9604SR

. Both models of adapter,

AP9505

and

AP9505

i, can be purchased separately from

APC

.

IF the LED is…

THEN the Silcon Triple Chassis…

off

is not receiving power.

flashing quickly

(5 times per second)

has not been configured. See “Configuring
via the Monitoring Port” on page 10.

blinking slowly

(1 time per second)

is powered on but is not communicating
with the UPS.

on

is operating normally.