Triton RT2000 X2 User Manual User Manual
Page 105

replace the SPED module.
601
ERR SPED REPORTED INVALID
ENCRYPT MODE
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
602
ERR SPED REPORTED
UNSUPPORTED CLEAR OPTION
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
603
ERR SPED REPORTED TAMPER
PRESENT
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
604
ERR SPED REPORTED INVALID KEY
INDEX
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
605
ERR SPED REPORTED PARENT KEY
NOT LOADED
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
606
ERR SPED REPORTED WRONG
DATA LENGTH
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
607
ERR SPED REPORTED PIN RETRY
TOO SOON
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
608
ERR SPED SELFTEST CRC FAILED
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
609
ERR SPED SELFTEST
CRYPTOGRAPHIC ERROR
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
610
ERR SPED SELFTEST BATTERY LOW
STATUS
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
611
ERR SPED SELFTEST SERIAL
NUMBER ERROR
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
612
ERR SPED TAMPER STATUS COLD
Verify all SPED connections. Restart the operating system. Clear
any errors conditions. Inspect the battery for a voltage reading of
greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.
Replace SPED module if error persists.
613
ERR SPED TAMPER STATUS FRONT
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
614 ERR_SPED_TAMPER_STATUS_BACK
Inspect cable from main board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
37