Triton RT2000 X2 User Manual User Manual
Page 103
570
Security module dev port setup
Inspect cable from main board assembly to the security module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, replace the security module.
571
Invalid default transaction
TBD
572
SPED key from pad cmd aborted by
user
Inspect cable from docking board assembly to the SPED module for damage.
Make sure that the cable is connected at both ends. Restart ATM. Clear the
error. If error persists, it may be necessary to replace the main board, the
docking board, the SPED module or related cabling.
573
SPED keys from pad cmd verify failed
Inspect cable from docking board assembly to the SPED module for
damage. Make sure that the cable is connected at both ends.
Restart ATM. Clear the error. If error persists, it may be necessary
to replace the main board, the docking board, the SPED module or
related cabling.
574
SNA comms error
To be determined
575
Timeout waiting to send command to
dispenser
Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.
576
Timeout waiting to receive response
from dispenser
Inspect the serial communication cables from the main board assembly to the
dispenser for damage. Make sure that each end of the cable is connected
securely. Replace the cable if it appear damaged. Check the power supply
for the proper DC operating voltages and that they are applied to the
dispenser mechanism. Possible defective components include main board
assembly, the docking board, the serial communications cables, the DC power
cables, the power supply, and the dispenser mechanism.
577
Card reader disabled
Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.
578
Card reader present timeout
Inspect card reader cable. Inspect the card reader for foreign objects.
Replace the cable or clean the card reader as needed. Clear the error.
Restart the ATM. If the error persists, replace the card reader.
579
SPED - Enable keypad command failed Inspect cable from docking assembly to the SPED Module for damage. Make
sure that the cable is connected at both ends. Verify that the DC operating
voltages are correct. Restart ATM. Clear the error. If error persists, replace
the SPED module.
580
SPED - Disable keypad command failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
581
SPED - Enable key from pad module
failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
582
SPED - Disable key from pad module
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
583
SPED - Enable PIN entry mode failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.
584
SPED - Disable PIN entry mode failed
Inspect cable from docking assembly to the SPED Module for
damage. Make sure that the cable is connected at both ends.
Verify that the DC operating voltages are correct. Restart ATM.
Clear the error. If error persists, replace the SPED module.