30
ARGO U
SER
M
ANUAL
4.
Close the cassette lid. Fold the lid down to its locked position. The release button should pop out allowing
the lid to mate cleanly with the body of the cassette. If applicable, lock the cassette with the cassette key.
5.
Replace the cassette into the dispenser using the reverse of the steps used to remove the cassette from the
dispenser. Slide the note cassette into its slot, making sure the cassette is fully inserted.
6. Repeat all steps for the other cassette.
Clearing Notes from the Reject Vault
1. Remove
vault.
While the security cabinet is open, remove the reject
vault by grasping the vault handle with one hand
while holding the mechanism in place with the other
hand. Pull the reject vault out slightly. Place one hand
underneath to support it as you slide it completely out
of the unit. Place it on a level surface.
2. Open vault and collect notes.
The reject vault is locked when it is removed from the
dispenser. A color indicator window shows
GREEN
when the vault is opened for collection and when it is
ready for use. This condition is also referred to as the
PRIME position of the color window.
The color window shows
RED
when the vault is
inserted into the dispenser and will show red until it
has been removed from the dispenser and opened for
collection.
Remove the vault seal (if applicable). Turn the small latch on the front counterclockwise and lift the lid.
Release the handle. Collect the rejected notes.
3. Close and replace vault.
After removing any rejected notes, turn the small latch about a half-turn counterclockwise and close the
lid. Allow the latch to return to the position of the seal bracket. At this point, the vault is primed and the
color window should be showing
GREEN
. If applicable, apply a new vault seal and lock the small latch
to the seal bracket.
Using the reverse of the steps taken to remove the reject vault, slide the reject vault back into its slot in
the dispenser. Make sure the vault is fully inserted.
O
l
d
ll
IMPORTANT: If you remove the reject vault
with power applied, the terminal will sense this
and automatically reset the rejected note count
to ZERO. Therefore, to ensure an accurate
rejected note count, never remove the reject
vault with power applied without removing any
rejected notes.
Removing the reject vault
Indicator window
Green
or
Red
Turn latch