© Copyright 2002. All rights reserved.
1. Read all instructions before beginning installation.
2. Be sure the installation does not exceed a maximum vertical lift of 19 feet.
3. Be sure the basin is level within 1/8 across the diameter.
4. Do not over torque extension tank attachment bolts.
5. Use backfill gravel that is larger than the slots in the basin.
1. DO read all installation material included with the pump.
2. DO inspect unit for any visible damage caused by shipping. Contact dealer
if unit appears to be damaged.
3. DO clean all debris from the pump reservoir.
4. DO always disconnect pump from power source before handling. DO
always connect to a separately protected and properly grounded ground
fault protected circuit. DO NOT ever cut, splice or damage power cord. DO
Ten Helpful Hints For Easy Installation
Dos And Don'ts For Installing A Unit
NOT carry or lift pump by its power cord. DO NOT use an extension cord
with this Crawl Space Pumping System.
5. DO NOT use a discharge pipe smaller than the diameter of the hose kit.
6. DO test pump immediately after installation to be sure that the system is
working properly.
7. DO review all applicable local and national codes and verify that the
installation conforms to each of them.
6. Test operation of pump per STEP 5.
7. Do not over tighten bushing, check valve, or hose clamp.
8. Plug pump into a properly grounded, constant voltage source.
9. Do not plug into a device that runs intermittently.
10. Obtain model number and date code prior to calling factory.
Performance Characteristics
009897
Crawl Space Pumping System
HEAD CAPACITY CURVE
CRAWL
SPACE