beautypg.com

Ratings and specifications 1.1. ratings, Gas pressure requirements, Caution! minimum clearances – Hired-Hand Bunsen Jet Brooders: Super-Saver Bunsen Jet (Radiant Brooder with Hot Surface Ignition) User Manual

Page 3: Warnings, Lp/propane gas: natural gas

background image

Part No. 4801-0062 rev 7-05

Super Saver Bunsen Jet

Page

3 of 18

1.

Ratings and Specifications

1.1. Ratings

Model No.

Maximum Input

Minimum Ventilation

(Air required to support combustion)

BJ-C-32-HIS

32,000 BTUH (9.38 kW)

320 CFM/brooder (543.6 m

3

/hr)

BJ-C-42-HSI

42,000 BTUH (12.31 kW)

420 CFM/brooder (713.6 m

3

/hr)

1.2. Gas Pressure Requirements

A maximum of 14 in. W.C. [34.8 mbar] and a minimum of 12.5 in.
W.C. [31.1 mbar] gas pressure is required at the inlet of the gas
valve. Burner manifold gas pressure is to be 11 in. W.C. [27.4
mbar] at maximum input rating. Gas pressure should be checked by
a certified gas technician, with maximum load on supply and while
brooder is in operation.

A maximum of 14 in. W.C. [34.8 mbar] and a minimum of 5 in.
W.C. [12.5 mbar] gas pressure is to be supplied to the inlet of the
gas valve. Burner manifold gas pressure is to be 3.5 in. W.C. [8.7
mbar] at maximum input rating. Gas pressure should be checked by
a certified gas technician, with maximum load on supply and while
brooder is in operation.

1.3. Caution! Minimum Clearances

These minimum clearances are calculated to show the safe operating boundaries. Do not operate the
brooder with walls, floor, ceiling, or other combustible objects within these limits.

Model

Ceiling

Wall

Floor

BJ-C-32-HSI

36 inches (92 cm)

36 inches (92 cm)

48 inches (122 cm)

BJ-C-42-HSI

36 inches (92 cm)

36 inches (92 cm)

48 inches (122 cm)

2. Warnings
















If you smell gas:

1. Open windows.

2. Don't touch electrical switches.
3. Extinguish any open flames.

4. Immediately call your gas supplier.

Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.


LP/Propane Gas:

Natural Gas:

1. Ouvrez les fenetres.

2. Ne touchez pas aux interrupteurs electriques.
3. Eteignez toute flamme nue.

4. Contactez immediatement votre compangie
de gaz.

ll es interdit d'utiliser des liquides
inflammables ou degageant des vapeurs
inflammables, a proximite de tout
appareil fonctionnant au gaz.

Si vous sentez une odeur de gaz: