6. Inspect and clean parts in solvent (de-natured alcohol) and blow-dry with compressed air. Replace worn

or damaged parts with new ones.

Installation:

1. Wrap two turns of 1/2" Teflon Tape around threads of CGA-580 Nipple (PN 57150) pressure fitting.

2. Hold CGA-580 nipple (PN 57150) pressure fitting in vise by flats located on nipple.

3. Slide CGA-580 nut (PN 57154) over threads of CGA-580 nipple (PN 57150) pressure fitting.

4. Thread and tighten adapter fitting (PN 60803) onto CGA-580 nipple (PN 57150) pressure fitting using a

3/4" wrench.

5. Remove assembly from vise and install a cheat seal pad (PN 54854) on AN thread side of adapter fitting

(PN 60803).

6. Thread into input hose and tighten using 3/4" and 9/16" wrenches.

4.2.20

AC Fuse (PN 57472), Removal and Installation

1. Disconnect the power cord from the power source and line filter. Remove the Fuse holder at POWER.

2. Inspect fuse, if blown replace with 1/2 Amp 250 Volt, 20mm x 5mm diameter ( PN 57472).

3. Replace the Fuse holder at POWER location.

4.2.21

Panel Mounted AC Power/EMI Line Filter (PN 58870), Removal and Installation

Tools required:

Phillips screwdriver
1/4" open end wrench or nutdriver
A/R soldering iron
A/R shrink sleeving (PN 60735)
A/R heat gun

1. Disconnect the power cord from the power source and line filter. Remove front panel from its enclosure

as described in Section 4.2.1 on page 16, and carefully set on a bench top.

2. Remove the 3 cable connectors from the line filter terminals.

NOTE: Some units may not have connectors and will have to have wire leads unsoldered.

3. Loosen and remove the line filter retaining nuts on the rear of panel.

NOTE: Some units may have screws on the front panel.

4. Remove the AC line filter.
5. To install a new line filter, reverse the order of steps 1 through 4. Connect (or solder) wires to the new

line filter as follows:

Green wire to terminal (E) Ground

White wire to terminal (N) Neutral

Black wire to terminal (P) Line

4.2.22

Chassis Mounted EMI Line Filter (PN 59015), Removal and Installation

Tools required:

Phillips screwdriver
1/4" open end wrench or nutdriver
A/R soldering iron
A/R shrink sleeving (PN 60735)
A/R heat gun

1. Disconnect the power cord from the power source and line filter. Remove front panel from its enclosure

as described in Section 4.2.1 on page 16, and carefully set on a bench top.

2. Remove the five cable connectors from the line filter terminals.
3. Loosen and remove the line filter retaining nuts on the side of chassis.
4. Remove the line filter.
5. To install a new line filter, reverse the order of steps 1 through 4.

Connect wires to the two wire side of new line filter as follows:

Blue wire to CPU White wire
Brown wire to CPU Black wire