beautypg.com

Condec UPC5210 User Manual

Page 19

background image

16

UPC5200/UPC5210 Operation and Maintenance Manual

4.2.1

Panel/Chassis Removal and Installation

UPC5200 Removal

Tools required:

Phillips screwdriver

1. Loosen and remove the 10 screws (PN 14862) that secure the panel assembly to the enclosure.

2. Lift the panel and chassis by first grasping the regulator knob and test port and second, grasping under

the panel edges. Tilt the panel at an angle by lifting the right side before the left side as you face the
panel. Ensure that the wire harnesses do not catch and snag.

3. Gently set the panel/chassis assembly on a bench top. It can be rested on the panel bottom with the

accumulator supported by a screwdriver handle.

UPC5200 Installation

Tools required:

Phillips screwdriver

1. Lift the panel and chassis by first grasping the regulator knob and test port.

2. Gently place panel/chassis assembly into enclosure. Tilt the panel at an angle by lifting the right side

before the left side as you face the panel. Ensure that the wire harnesses do not catch and snag.

3. Align mounting holes and install the 10 screws (PN 14862) that secure the panel assembly to the

enclosure.

UPC5210 Removal

Tools required:

Phillips screwdriver

1. Loosen and remove the 14 screws (PN 14861) from top, bottom, and sides that secure the panel assembly

to the enclosure. Also, loosen and remove the three screws (P/N 14861) from the rear of unit that secure
the enclosure to the AC INPUT/INPUT PORT panel.

2. Lift the panel and chassis by grasping the handles located on the front of the rack mountable panel.

Ensure that the wire harnesses do not catch and snag.

3. Gently set the panel/chassis assembly on a bench top. It can be rested on the panel bottom with the

accumulator supported by a screwdriver handle.

UPC5210 Installation

Tools required:

Phillips screwdriver

1. Lift the panel and chassis by grasping the handles located on the front of the rack mountable panel..

2. Gently place panel/chassis assembly into enclosure. Ensure that the wire harnesses do not catch and

snag.

3. Align mounting holes and install 14 screws (PN 14862) from top, bottom, and sides that secure the

panel/chassis assembly to the enclosure. Also, align mounting holes and install the three screws (P/N
14862) from the rear of unit that will secure the enclosure to the AC INPUT/INPUT PORT panel.

4.2.2

Accumulator, Intensifier & ORION-3A (PN 55287) Removal

Tools required:

Phillips screwdriver
11/32" wrench or nutdriver
.061" hex wrench
adjusting screwdriver (small flat blade)
11/32" open end wrench (thin)
7/16" open end wrench

NOTE:

See Table 4-2 on page 34 and Figure 4-2 on page 35 for additional

ORION-3A

parts information.

1. Vent the system to atmosphere before attempting to work on the unit. Disconnect the power cord from

the power source.

2. Remove front panel from its enclosure as described in Section 4.2.1 and carefully set on a bench top.

3. Using a 7/16" wrench, remove the following tubing sections:

Accumulator to supply pressure gauge (1/8" dia.)

Accumulator to pressure inlet on ORION-3A manifold (1/8" dia.)

Accumulator to intensifier outlet (1/4" dia.)

This manual is related to the following products: