16
UPC5200/UPC5210 Operation and Maintenance Manual
4.2.1
Panel/Chassis Removal and Installation
UPC5200 Removal
Tools required:
Phillips screwdriver
1. Loosen and remove the 10 screws (PN 14862) that secure the panel assembly to the enclosure.
2. Lift the panel and chassis by first grasping the regulator knob and test port and second, grasping under
the panel edges. Tilt the panel at an angle by lifting the right side before the left side as you face the
panel. Ensure that the wire harnesses do not catch and snag.
3. Gently set the panel/chassis assembly on a bench top. It can be rested on the panel bottom with the
accumulator supported by a screwdriver handle.
UPC5200 Installation
Tools required:
Phillips screwdriver
1. Lift the panel and chassis by first grasping the regulator knob and test port.
2. Gently place panel/chassis assembly into enclosure. Tilt the panel at an angle by lifting the right side
before the left side as you face the panel. Ensure that the wire harnesses do not catch and snag.
3. Align mounting holes and install the 10 screws (PN 14862) that secure the panel assembly to the
enclosure.
UPC5210 Removal
Tools required:
Phillips screwdriver
1. Loosen and remove the 14 screws (PN 14861) from top, bottom, and sides that secure the panel assembly
to the enclosure. Also, loosen and remove the three screws (P/N 14861) from the rear of unit that secure
the enclosure to the AC INPUT/INPUT PORT panel.
2. Lift the panel and chassis by grasping the handles located on the front of the rack mountable panel.
Ensure that the wire harnesses do not catch and snag.
3. Gently set the panel/chassis assembly on a bench top. It can be rested on the panel bottom with the
accumulator supported by a screwdriver handle.
UPC5210 Installation
Tools required:
Phillips screwdriver
1. Lift the panel and chassis by grasping the handles located on the front of the rack mountable panel..
2. Gently place panel/chassis assembly into enclosure. Ensure that the wire harnesses do not catch and
snag.
3. Align mounting holes and install 14 screws (PN 14862) from top, bottom, and sides that secure the
panel/chassis assembly to the enclosure. Also, align mounting holes and install the three screws (P/N
14862) from the rear of unit that will secure the enclosure to the AC INPUT/INPUT PORT panel.
4.2.2
Accumulator, Intensifier & ORION-3A (PN 55287) Removal
Tools required:
Phillips screwdriver
11/32" wrench or nutdriver
.061" hex wrench
adjusting screwdriver (small flat blade)
11/32" open end wrench (thin)
7/16" open end wrench
NOTE:
See Table 4-2 on page 34 and Figure 4-2 on page 35 for additional
ORION-3A
parts information.
1. Vent the system to atmosphere before attempting to work on the unit. Disconnect the power cord from
the power source.
2. Remove front panel from its enclosure as described in Section 4.2.1 and carefully set on a bench top.
3. Using a 7/16" wrench, remove the following tubing sections:
•
Accumulator to supply pressure gauge (1/8" dia.)
•
Accumulator to pressure inlet on ORION-3A manifold (1/8" dia.)
•
Accumulator to intensifier outlet (1/4" dia.)