External antenna suspended ceiling tile (Plenum) mount

2

20

Brocade Mobility 1220 Access Point Installation Guide

53-1002916-01

External antenna suspended ceiling tile (Plenum)
mount

Ceiling mount requires placing the Mobility 1220 Access Point above suspended
ceiling tile.

NOTE

Notes or warnings about suspended ceiling mounts apply to all installations where
the unit is placed on suspended ceiling tile.

CAUTION

Brocade does not recommend mounting the Mobility 1220 Access
Point directly to any suspended ceiling tile with a thickness less than
12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span
greater than 660mm (26in.). Brocade strongly recommends fitting the
Brocade Mobility 1220 with the supplied mounting ears and hanging
the access point on a pipe or beam.

Suspended ceiling mount hardware

Security cable (optional)

Mounting ears

Customer supplied pipe or channel clamps

Ceiling mount procedure

1. If possible, remove the ceiling tile from its frame and place it, finish side down,

on a work surface.

2. If required, install and attach a Kensington security cable (customer provided)

to the unit’s lock port.

3. Place the access point on the ceiling tile or attach to a plenum beam or pipe

using industry available clamps.

4. Attach appropriate antennas to the connectors.