Suspended ceiling mount hardware, Ceiling mount procedure – Brocade Mobility 1220 Access Point Installation Guide User Manual
Page 25
![background image](/manuals/361706/25/background.png)
External antenna suspended ceiling tile (Plenum) mount
2
20
Brocade Mobility 1220 Access Point Installation Guide
53-1002916-01
External antenna suspended ceiling tile (Plenum)
mount
Ceiling mount requires placing the Mobility 1220 Access Point above suspended
ceiling tile.
NOTE
Notes or warnings about suspended ceiling mounts apply to all installations where
the unit is placed on suspended ceiling tile.
CAUTION
Brocade does not recommend mounting the Mobility 1220 Access
Point directly to any suspended ceiling tile with a thickness less than
12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span
greater than 660mm (26in.). Brocade strongly recommends fitting the
Brocade Mobility 1220 with the supplied mounting ears and hanging
the access point on a pipe or beam.
Suspended ceiling mount hardware
•
Security cable (optional)
•
Mounting ears
•
Customer supplied pipe or channel clamps
Ceiling mount procedure
1. If possible, remove the ceiling tile from its frame and place it, finish side down,
on a work surface.
2. If required, install and attach a Kensington security cable (customer provided)
to the unit’s lock port.
3. Place the access point on the ceiling tile or attach to a plenum beam or pipe
using industry available clamps.
4. Attach appropriate antennas to the connectors.