26
Multi-Service IronWare SDN Configuration Guide
53-1003034-02
Configuring OpenFlow
1
Total number of data bytes sent to controller:
0
Flow ID: 1 Priority: 32768 Status: Active
Rule:
In Port: e1/2
In Vlan: Untagged
Destinaltion Mac: 000.0000.0001
Destination Mac Mask:FFFF.FFFF.FFFF
Action: FORWARD
Out Port: e1/1, Untagged
Statistics: 0
Total Pkts: 0
Total Bytes: 0
Flow ID: 2 Priority: 32768 Status: Active
Rule:
In Port:
e1/2
In Vlan:
Tagged [10]
Vlan PCP:
4
Destinaltion Mac: 0000.0000.0001
Destination Mac Mask:FFFF.FFFF.FFFF
Action: FORWARD
Out Port: e1/1, Untagged
Out Port: e1/3, Untagged
Statistics: 0
Total Pkts: 0
Total Bytes: 0
TABLE 9
Output fields for the show openflow flows command
Field
Description
Total Number of Flows
The total number of flows on the device.
Total number of data
packets sent to controller
The number of packets sent to the controller.
Total number of data
byte sent to controller
The number of bytes sent to the controller.
Flow ID
An identifier for each flow. You can use the flow ID from this output to display
flow-specific details.
Priority
The priority of the flow set by the controller when the flow is added, in the range 0 to
65536. If the priority value was not specified, the Brocade device will assign the
default value, 32768.
Status
Indicates whether the flow is configured correctly in the device. A correctly configured
flow will have its status as ACTIVE.
Rule
Specifies the matching rule for the flow. In this example, the matching rule is for the
flow with Flow ID 1, to forward untagged packets reaching the interface eth 1/2 with
the destination MAC address of 0000.0000.0001, to the egress port eth 1/1 as
untagged packets.
Here, the destination MAC Address Mask of FFFF.FFFF.FFFF indicates that only packets
exactly matching the specified destination MAC address will be forwarded.
Statistics
Indicates the counter of packets and bytes. For Brocade NetIron CER and Brocade