GEO

S12

HARDWARE SETUP PROCEDURE

Alternative Procedure

(“Walder” procedure)

Below described procedure required 2 additional 8x20 quick release pins (BLGEOS)

Split the GPT-PSBRK side plates by removing screws and bolt;

Slide GPT-PSBRK lower half-plates into lower GEO S12 connecting plate oblong holes;

Lock safety pins into lower GEO S12 connecting plate;

Position “U” bracket over these lower half plates; align centre holes;

Insert adjustment handles, adjust vertical angle and tight the handles to prevent GEO
S12 from rotating around “U” bracket;

Lift assembly on Wind Up stand or on LS18 with PLSTD pole stand.

Slide GPT-PSBRK upper half-plates into upper GEO S12 connecting plate oblong
holes;

Lock safety pins into upper GEO S12 connecting plate;

Lift upper GEO S12 on top of lower one, and connect them together by inserting 8x20
quick release pins in articulation holes;

Adjust inter-cabinet angle and lock to required angle value with quick release pins.

IMPORTANT

Ensure that safety pins are properly locked into GEO S12 connecting panels.