Required items, Procedure – Nexo LS18 User Manual
Page 34
Page 34/103
GEO
S12
HARDWARE SETUP PROCEDURE
8.3.2 Single GEO S12 rigidly mounted on a wall or a ceiling (vertical or horizontal)
Required items
1 x GEOS12-UBRK (allows all angles to be implemented)
4 x 12mm diameter screws (not provided)
IMPORTANT
Ensure that the surface
– wall or ceiling – is strong enough to hold GEO S12 weight and
that the for screws 12mm diameter and corresponding plugs
required to fix the “U”
bracket on the wall or under the ceiling are properly dimensioned.
Procedure
For screws 12mm diameter (not provided) are required to secure the “U” Bracket on the
wall or ceiling;
Remove the four TORX screws holding connector plates on both sides of GEO S12;
Position the GEO S12 inside the “U” Bracket to desired angle; “U” bracket oblong holes
must be properly aligned with panels holes;
Apply Loctite 243 or equivalent to the eight screws and washers from VNI-UBRK12 kit;
Connect “U” bracket to cabinet with these screws.