MAHLE RTI RHS980C User Manual
Page 29

28
DEFAULT VALUES
D E F A U L T V A
L
U
E
S
C O N T I N U E ?
F I L L C Y L I N D E R T A R G E T
A M O U N T # # . # # L B
B E T W E E N 6 . 6 & 2 4 . 2 L B
C O N T I N U E ?
I N I T I A L V A C U U M H O L D
#
# # # # M I C
R
O
N
B E T W E E N 3 K & 9 K
C O N T I N U E ?
F I N A L V A C U U M L E V E L
#
# # # # M I C
R
O
N
B E T W E E N 1 K & 9 K
C O N T I N U E ?
V A C U U M R U N T I M E
# # M I N
B E T W E E N 1 & 9 9 M I N
C O N T I N U E ?
H O S E S O V E R C H A R G E
A
M
O
U
N
T # . # # K
G
B E T W E E N 0 & 0 . 9 9 K G
C O N T I N U E ?
D E F A U L T M I N I M U M L I N E
V O L T A G E # # # V A
C
B E T W E E N 9 0 & 1 2 0 V A C
C O N T I N U E ?
E L E V A T I O N F R O M S E A
L E V E L # # # # # F T
B E T W E E N 0 & 3 0 K F E E T
C O N T I N U E ?
Press START key.
The Fill Cylinder procedure will automatically transfer 
refrigerant from a new cylinder of refrigerant to the 
internal RHS980C charge cylinder. The value set here 
will be the amount of refrigerant which will have been 
transferred when the procedure stops automatically. 
Enter an amount between 3 and 11 KG (6.6 and 24.2 
LB). The value will be displayed as it is entered. Press 
START key. (Default is 8.00 KG (17.6 LB)) 
The A/C system will be checked for leaks during the 
vacuum process. This test will pull the A/C system into 
a vacuum and then pause for a period of 60 seconds. 
If the vacuum level decreases, it’s an indication that 
the A/C system has a leak. Enter an amount between 
3000 and 9000 micron of vacuum. The value will be 
displayed as it is entered. Press START key. (Default 
is 5000 MICRON) 
This screen allows the adjustment of the final vacuum 
micron level check performed. After the vacuum 
procedure is completed, the level achieved must be at 
least this value or a failure message is displayed. 
Press START key. (Default is 2000 MICRON) 
This screen prompts for the length of time the vacuum 
pump will run during each cycle. There is one initial 
cycle to pull the system for an initial vacuum leak test, 
then a second cycle to obtain the final micron level. 
Enter a number of minutes between 1 and 99. The 
value will be displayed as it is entered. Press START 
key. (Default is 10 MIN) 
A small overcharge of refrigerant is necessary to 
compensate for refrigerant which will remain in the 
hose after a charge procedure. Enter the number of 
KG between 0 and 0.99 (0 and 2.2 LB). The value will 
be displayed as it is entered. Press START key. 
(Default is 0.02 KG (0.04 LB)) 
During machine operation, the line voltage is 
monitored to remain above a threshold to ensure 
correct operation. Enter number of volts between 90 
and 120VAC. The value will be displayed as it is 
entered. Press START key. (Default is 90 V AC) 
Elevation from sea level to adjust pressure transducer 
calibration. Enter a number in feet from 0 to 30,000 
feet. The elevation can be obtained by calling your 
local airport. (Default is 400 FT) 