Operation – Lincoln Electric IM10038 POWER WAVE C300CE User Manual
Page 53

B-33
OPERATION
B-33
POWER WAVE® C300 CE
USER DEFINED PARAMETERS
Parameter
Definition
P.27
Language Select
Selects which language will be displayed on the User Interface.
English (Default)
Italiano
Deutsch
Francais
Polski
Espanol
P.28
Display Workpoint as Amps Option
This option determines how workpoint is displayed.
False = The workpoint is displayed in the format defined in the weld set (default).
True = All workpoint values are displayed as an amperage.
Note: This option may not be available on all machines. The power source must support this func-
tionality, or this option will not appear in the menu.
P.29
Feedback Persist
This option determines how feedback values are displayed following a weld.
False = Last recorded feedback values will blink for 5 seconds following a weld, then return to pre-
set display mode (default).
True = Last recorded feedback values will blink indefinately following a weld until a knob or button
is touched, or an arc is struck.
P.80
Sense From Studs
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other machine
settings (default).
True = Voltage sensing is forced to "studs".
P.82
Voltage Sense Display
Allows viewing of Voltage Sense Lead Selection to aid in troubleshooting. The configuration is dis-
played as a text string on the lower display whenever the output is enabled. This parameter is not
saved on a power cycle, but will be reset to False.
P.99
Show Test Modes?
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the opera-
tor. To manually select a test weld mode, set this option to "Yes". When the power source is turned
off and back on again, the test modes will no longer appear in the mode list. Test weld modes typi-
cally require the machine output to be connected to a grid load and cannot be used for welding.
P.100
View Diagnostic?
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes" to
access the diagnostic options in the menu. Additional parameters will now appear in the setup
menu (P.101, P.102, etc).
P.101
View Event Logs
Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate
Control Knob to select the desired event log to read. Press the Right Button again to enter the
selected log. Rotating the Control Knob will scroll through the event log, displaying the log index
number, event code and some other data. Press the Left Button to back out to select another log.
Press the Left Button again to exit this option.