beautypg.com

Operation, Job4, B-18 – Lincoln Electric IM10038 POWER WAVE C300CE User Manual

Page 38: Limits

background image

B-18

OPERATION

B-18

Press the Left Push Button until Memory 'M' LED
is illuminated.

Rotate center knob to cycle to desired memory.

Press and hold center knob for 5 seconds. The
Set Limits Menu will be active.

POWER WAVE® C300 CE

LIMITS

Limits allow the welder to adjust the welding proce-
dure only within a defined range.

Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memo-
ry 3 may not have any WFS limits.

Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.

The system machine limits are:

Parameter

Wire Feed Speed

Voltage

Trim

UltimArc™Control

Preflow

Start Time

Run-In WFS

Crater Time

Burnback Time

Postflow Time

Range

Weld mode and wire

feeder dependent.

Weld mode dependent

0.50 to 1.50

-10.0 to 10.0

0.0 to 2.5

0.0 to 10.0

Off, 50 to 150

0.0 to 10.0

0.00 to 0.25

0.0 to 10.0

Units

in/min

Volts

--

Weld mode dependent

Seconds

Seconds

in/min

Seconds

Seconds

Seconds

Limits may be set for:

• Wire Feed Speed/Amperage
• Voltage/Trim
• UltimArcTM Control

Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to mem-
ory before entering the Limits Setup Menu.

+

+

A

Job1

Steel
CV

1.2mm
Ar Mix

V

M

4T

“M Led”

+

+

A

Job4

Stainless
Pulse

1.0mm
Ar Mix

V

M

4T

+

+

A

Memory 4
Set Limits

V

M

4T

Press and Hold Knob for
5 second. Limits is active.

5 SECONDS

PRESS