beautypg.com

Operation, Parameter, Definition – Lincoln Electric IM10038 POWER WAVE C300CE User Manual

Page 47

background image

B-27

OPERATION

B-27

POWER WAVE® C300 CE

SET-UP FEATURES MENU

(See Figure B.16)

1. To access the set-up menu, press the Right and

Left buttons of the Main Display panel simultane-
ously. Note that the set-up menu cannot be
accessed if the system is welding, or if there is a
fault (The status LED is not solid green).

Change the value of the blinking parameter by rotat-
ing the SET knob.

2. After changing a parameter it is necessary to press

the Right hand button to save the new setting.
Pressing the Left button will cancel the change.

3. To exit the set-up menu at any time, press the

Right and Left buttons of the Main Display panel
simultaneously. Alternately, 1 minute of inactivity
will also exit the set-up menu.

The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters
that generally only need to be set at installation. The parameters are grouped as shown in the following table.

SETUP MENU FEATURES

PARAMETER

P.1 through P.99

P.101 through P.199
P.501
through P.599

DEFINITION

Unsecured Parameters (always adjustable)

Diagnostic Parameters (always read only)

Secured Parameters (only accessible through a p.c. or palm application)

LED

Set-Up

Mode

Mode Select

Main Display Panel

Right

button

SET Knob

Left

button

FIGURE B.16 - SETUP MENU