A-1

INSTALLATION

POWER WAVE® C300 CE

A-1

TECHNICAL SPECIFICATIONS - POWER WAVE® C300 CE

RECOMMENDED INPUT WIRE AND FUSE SIZES

1

INPUT

VOLTAGE /

PHASE/

FREQUENCY

208/3/50/60
230/3/50/60
400/3/50/60
460/3/50/60
575/3/50/60

TIME DELAY FUSE

OR BREAKER

SIZE

2

(AMPS)

40
40
25
20
15

CORD SIZES

3

AWG SIZES (mm

2

)

8 (10)
8 (10)
12 (4)

14 (2.5)
14 (2.5)

INPUT AMPERE

RATING ON

NAMEPLATE

30
28
16
14
11

RATED OUTPUT

POWER SOURCE-INPUT VOLTAGE AND CURRENT

Model

K2865-1

Duty Cycle

40% rating

100% rating

Volts at Rated Amperes

29

26.5

31.2

29

22

20

Amperes

300

250

280

225

300

250

Duty Cycle

40%

100%

40%

100%

40%

100%

Process

GMAW

GMAW-Pulse

FCAW

SMAW

GTAW-DC

Input Amperes

30/28/16/14/11

23/21/12/11/9

Idle Power

300 Watts Max.

(fan on)

Power Factor @

Rated Output

.95

Input Voltage ± 10%

208/230/400*/460/575

3 phase 50/60 Hz

(* includes 380V to 415V)

1 Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2 Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the

magnitude of current increases.