TANK-800 Embedded System

Page 37

3.9 Redundant Power

The TANK-800 is a system that supports redundant power. The redundant power input

increases the reliability of the system and prevents data loss and system corruption from

sudden power failure. The system can instantly and uninterruptedly switch to the second

power input when the main power is unavailable or in low voltage capacity.

There are two power connectors on the rear panel. Power 1 connector is a 3-pin terminal

block that supports ACC On signal. Power 2 connector is a DIN connector that can directly

connect to a power adapter. The supported power input voltages are:

ƒ

Power 1: 9 V (+/-0.3 V) ~ 36 V

ƒ

Power 2: 10.5 V (+/-0.3 V) ~ 36 V

Figure 3-26: Power Connectors

When the system is in ACC On mode, the main power input is from Power 1 connector;

when the system is in ACC Off mode, the main power input is from Power 2 connector. The

ACC on/off mode is selected by the ACC mode switch on the rear panel (Figure 3-10).

The following sections describe how the redundant power works in ACC On mode and

ACC Off mode.