12 serial port console redirection – IEI Integration KINO-QM770 User Manual
Page 115

KINO-QM770 Mini-ITX SBC
Page 99
Î SYS Fan Smart Fan Control [Auto Duty-Cycle Mode]
Use the SYS_FAN1 Smart Fan Control option to configure the System Smart Fan
(SYS_FAN1).
Î
Manual Duty
Mode
The fan spins at the speed set in Manual by Duty
Cycle settings
Î
Auto Duty-Cycle
Mode
D
EFAULT
The fan adjusts its speed using Auto by
Duty-Cycle settings
Î Fan start/off temperature
Use the + or – key to change the Fan start/off temperature value. Enter a decimal
number between 1 and 128.
Î Fan start PWM
Use the + or – key to change the Fan start PWM value. Enter a decimal number between
1 and 128.
Î Fan slope PWM
Use the + or – key to change the Fan slope PWM value. Enter a decimal number between
1 and 64.
Î Temperature n
Use the + or – key to change the fan Temperature n value. Enter a decimal number
between 1 and 100.
5.3.12 Serial Port Console Redirection
The Serial Port Console Redirection menu (BIOS Menu 16) allows the console
redirection options to be configured. Console redirection allows users to maintain a
system remotely by re-directing keyboard input and text output through the serial port.