beautypg.com

B−30, B 30 – XLT Hitachi X200 User Manual

Page 273

background image

List of Holding Registers

Network Data

Func.

Code

Name

R/W

Description

Reg.

Range

Res.

A104

[OI]-[L] input active
range end voltage

R/W The ending point (offset) for the

current input range,
range is 0. to 100.%

1084h

0 to 100

1 %

A105

[OI]-[L] input start
frequency enable

R/W Two options; select codes:

00

}Use offset (A101 value)

01

}Use 0Hz

1085h

0, 1

A141

A input select for
calculate function

R/W Five options:

00

}Digital operator

01

}Keypad potentiometer

02

}[O] input

03

}[OI] input

04

}Network variable

108Eh

0 to 4

A142

B input select for
calculate function

R/W Five options:

00

}Digital operator

01

}Keypad potentiometer

02

}[O] input

03

}[OI] input

04

}Network variable

108Fh

0 to 4

A143

Calculation symbol

R/W Calculates a value based on the

A input source (A141 selects) and
B input source (A142 selects).
Three options:
00

}ADD (A input + B input)

01

}SUB (A input - B input)

02

}MUL (A input * B input)

1090h

0, 1, 2

A145

ADD frequency

R/W An offset value that is applied to

the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.0 Hz

1091h

0 to 4000

0.1 Hz

A146

ADD direction select

R/W Two options:

00

}Plus (adds A145 value to the

output frequency setting)
01

}Minus (subtracts A145 value

from the output frequency etting)

1093h

0, 1

A151

POT active range start
frequency

R/W The output frequency

corresponding to the POT range
starting point,
range is 0.0 to 400.0 Hz

1095h

0 to 4000

0.1 Hz

A152

POT input active range
end frequency

R/W The output frequency

corresponding to the POT range
ending point,
range is 0.0 to 400.0 Hz

1097h

0 to 4000

0.1 Hz

A153

POT input active range
start

R/W The starting point (offset) for the

POT range, range is 0. to 100.%

1098h

0 to 100

1 %

A154

POT input active range
end

R/W The ending point (offset) for the

POT range, range is 0. to 100.%

1099h

0 to 100

1 %

A155

POT input start
frequency enable

R/W Two options; select codes:

00

}Use offset (A151 value)

01

}Use 0Hz

109Ah

0, 1

Note 1:

When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored. (for A092/A292 and A093/A293).

B

30

Appe

ndix B

B

−30

Appendix B