Jump Frequencies – Some motors or machines exhibit resonances at particular speed(s),
which can be destructive for prolonged running at those speeds. The inverter has up to
three

jump frequencies

as shown in the graph. The hysteresis around the jump

frequencies causes the inverter output to skip around the sensitive frequency values.

“A” Function

Defaults

Func.

Code

Name /

SRW Display

Description

Run

Mode

Edit

-FE

(EU)

-FU

(USA)

Units

Jump (center) frequency
setting

A063,
A065,
A067

JUMP F1

0000.0Hz

JUMP F2

0000.0Hz

JUMP F3

0000.0Hz

Up to 3 output frequencies can be
defined for the output to jump
past to avoid motor resonances
(center frequency)
Range is 0.0 to 400.0 Hz

U

0.0
0.0
0.0

0.0
0.0
0.0

Hz

Jump (hysteresis) frequency
width setting

A064,
A066,
A068

JUMP W1

0000.5Hz

JUMP W2

0000.5Hz

JUMP W3

0000.5Hz

Defines the distance from the
center frequency at which the
jump around occurs
Range is 0.0 to 10.0 Hz

U

0.5
0.5
0.5

0.5
0.5
0.5

Hz

Output

frequency

Frequency

command

A065

A067

A063

A064

A064

A066

A066

A068

A068

3

21

Config

uri
ng Driv

e

Parameters

3

−21

&RQ¿JXULQJ'ULYH

Parameters