OSD MENU

Description

TEMPERATURE SETUP
TEMPERATURE FORMAT

HIGH THRESHOLD

LOW THRESHOLD

DVR HOT PROTECT

055

030

035

C

TEMPERATURE SETUP

Set the DVR unit temperature type and high/low threshold limit.

TEMPERATURE FORMAT:

Temperature pattern display on front LED panel.

HIGH THRESHOLD:

Set a specific temperature limited (0 ~ 100°C) for fan active.
When the hard disk temperature is higher than limited
temperature, the fan will be active. The default value is 35°C.

LOW THRESHOLD:

Set a specific temperature limited (0 ~ 30°C) for fan stop. When
the hard disk temperature is lower than limited temperature, the
fan will be stop. The default value is 30°C.

DVR HOT PROTECT:

Set the temperature limit to shutdown hard disk when the DVR
unit temperature is higher than (>) limited (55 ~ 70°C).