Vanguard CT-6500 S2 User Manual
Page 55

CT-6500 Series 2 Operating Instructions
54
9.11 Select English or Metric Measurement Unit.
The CT-6500 supports and displays both English and Metric calculations from the breaker's
travel parameters such as the stroke, velocity and other parameters. The user can switch from
one system to the other by following the steps in Table 16.0.
Table 16.0 Select English or Metric Procedure
STEP OPERATION
ACTION
DISPLAY
1
SELECT SET UP MENU.
PRESS # 3 KEY.
1.ANALYSIS POINT
2.MEASUREMENT UNITS
3.SAVE / RESTORE
4.NEXT PAGE
2
MEASUREMENT UNITS.
PRESS # 2 KEY.
SELECT UNITS
1.ENGLISH
2.METRIC
3.ROT ENC 4.RES ENC
3
SELECT METRIC UNIT
PRESS # 2 KEY.
1.RUN TEST 06/10/07
2.GET RESULTS 20:10:01
3.SETUP
4.DIAGNOSTIC
9.12 Digital Rotary Transducer Selection
A rotary transducer requires the user to enter the defined linear distance in millimeters or
inches, per one degree of rotary motion as seen in Table 17.0.
Table 17.0 Select Rotary Transducer
STEP OPERATION
ACTION
DISPLAY
1
SELECT SET UP MENU.
PRESS # 3 KEY.
1. ANALYSIS POINT
2. MEASUREMENT UNITS
3. SAVE / RESTORE
4. NEXT PAGE
2
SELECT MEASUREMENT UNITS.
PRESS # 2 KEY.
SELECT UNITS
1. ENGLISH
2. METRIC
3. ROT ENC 4. RES ENC
3
SELECT ROTARY TRANSDUCER.
PRESS # 3 KEY.
ROTARY ENCODER:
1. ENGLISH (In./deg)
2. METRIC (MM/deg)
4
SELECT INCH PER DEGREE.
PRESS #1 KEY.
INCHES/DEGREE
0.014 in/deg
5
ENTER 0.50 INCH PER DEGREE.
ENTER 0.50 USING
0-9 KEYS.
INCHES/DEGREE
0.500 in/deg
6
RETURN TO MAIN MENU.
PRESS THE
“ENTER” KEY.
1.RUN TEST 06/10/07
2.GET RESULTS 20:10:01
3.SETUP
4.DIAGNOSTIC