Clean up/reinspection, Description – Tracer TP-9850-70 EZ-Ject AM05021 User Manual
Page 2

Do not mix dyes. Always use the dye cartridge with its designated hose assembly. The hose assembly can be stored
containing dye.
•
TP-9850 for R-12/mineral oil systems
•
TP-9860 for R-134a/PAG systems
•
TP-9870 Universal dye is compatible with all refrigerants and lubricants
CLEAN UP/REINSPECTION
After the leaks are repaired, clean the remaining dye from the leak sites with a cloth and Tracer Products’ GLO-AWAY™ dye cleaner or
a general purpose shop cleaner. Check with the lamp to be sure all dye is removed. Residual dye could give a false leak indication.
Run the A/C system another 5 to 10 minutes and reinspect with the lamp. No glow means that all the leaks have been found and
repaired.
DYE CAUTIONS
•
Keep out of reach of children.
•
Wipe all dye spills immediately. May damage paints and finishes. May stain hands and clothing.
•
Store in a cool place away from sunlight.
NO. PART
NO. DESCRIPTION
1 TP-9845
EZ-JECT
ASSEMBLY
3
TP-9850
CARTRIDGE, DYE, R-12/MINERAL OIL
5 TP-9860
CARTRIDGE,
DYE,
R-134A/PAG
7
TP-9870
CARTRIDGE, DYE, R-134A/ESTER “UNIVERSAL”
9
TP-9846
HOSE ASSEMBLY, R-12, WITH COUPLER
11
119690
PURGE FITTING, ¼” FLARE
13
TP-9847
HOSE ASSEMBLY, R-134A WITH COUPLER, LOW-SIDE
15
TP-9849
HOSE ASSEMBLY, R-134A, WITH COUPLER, HIGH-SIDE
17
TP-3888
QUICK COUPLER, R-134A, LOW SIDE
19
TP-9888
QUICK COUPLER, R-134A, HIGH SIDE
21
107472
ADAPTER/PURGE FITTING, R-134A, LOW-SIDE
23
107949
ADAPTER/PURGE FITTING, R-134A, HIGH-SIDE
8/05 AM05021