5. One second after step 4, the test system modifies the beacons in slot 2 with a
BPOIE indicating that device with a DevAddr of 3 is occupying slot 3 and a device
with a DevAddr of 4 is occupying slot 4 and modifies the BP Length to 14.
6. Steps 4-5 are repeated with additional beacons slots occupied each time until the
test system is occupying slots 3-95.
7. Note: Once the BP Length reaches 96 it is no longer incremented.
8. After 1 second, test system stops beaconing.
9. After at least 2 seconds, stop the analyzer capture.
Notes:
• The DUT or INTD are allowed to cease demonstrating operation and/or beacon
transmission at any point after beacon slot relocation would place them in a
beacon slot higher than slot 20.
Test Case 2.1: TD.8.4.1.2 Conflicting Reservation – Whole Superframe – Alien BP
This test verifies that a DUT will not transmit in reservations advertised by other devices
when it receives beacons indicating reservations with conflicting types for the same
MAS.
Test procedure:
1.
Start analyzer capture.
2.
Test system starts the beacon period and sends a beacon in slot 2 with a BPOIE
that indicates that slots 3, 4, 5, and 6 are occupied. The BP Length is set to 16.
3.
Standard test start-up sequence.
4.
The test system begins to transmit beacons in slots 3, 4, 5, and 6 that contain
DRP IEs that reserve the whole superframe except the first 5 MAS with
reservation type Alien BP.
5.
After 2 seconds, test system stops beaconing.
6.
After at least 2 seconds, stop analyzer capture.
Notes:
In addition to passing the normal background checks, the following compliance points
are manually verified:
• The DUT/INTD cease sending CTRL / DATA packets in the same SF in which
the tester introduces its conflicting DRP IE