beautypg.com

11 irecoptions::setsaveexternalsignals, Irecoptions::setsaveexternalsignals – Teledyne LeCroy Automation API for Bluetooth Analyzers User Manual

Page 66

background image

60

Automation API for CATC Bluetooth Analyzers

CATC

Ver. 1.40

2.5.11 IRecOptions::SetSaveExternalSignals

Sets the flag indicating to save external signals

Parameters

save

-

TRUE – save external signals, FALSE – do not save external signals

Return values

Remarks

By default external signals are not saved.

Example

WSH:

CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName,

"\"))

Set Analyzer = WScript.CreateObject("CATC.Merlin")

Set RecOptions = Analyzer.GetRecordingOptions

RecOptions.SetSaveExternalSignals TRUE

C++:

HRESULT SetSaveExternalSignals (

[in] BOOL save );