beautypg.com

3 irecoptions::setrecmode, Irecoptions::setrecmode – Teledyne LeCroy Automation API for Bluetooth Analyzers User Manual

Page 58

background image

52

Automation API for CATC Bluetooth Analyzers

CATC

Ver. 1.40

2.5.3 IRecOptions::SetRecMode

Sets the recording mode

Parameters

rec_mode

-

enumerated value providing the mode to set;

ErecModes

enumerator has

the following values:

RMODE_SNAPSHOT

( 0 ) –

snapshot recording mode

RMODE_MANUAL

( 1 ) –

manual trigger

RMODE_USE_TRG

( 2 ) –

event trigger

Return values

E_INVALIDARG

invalid recording mode was specified

Remarks

The default setting of recording options is a snapshot recording mode.

Example

WSH:

CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName,

"\"))

Set Analyzer = WScript.CreateObject("CATC.Merlin")

Set RecOptions = Analyzer.GetRecordingOptions

RecOptions.SetRecMode 2' Event trigger

C++:

HRESULT SetRecMode (

[in] ERecModes rec_mode );