• DIVF – Modbus Communication Module (Part No. 9568) – Allows the drive to communicate with

PLCs, PCs, and HMIs with Modbus RTU protocol utilizing a serial communication cable. If a USB

communication cable is required, purchase Part No. 19008.

• Custom Software – All models can be factory programmed for applications which require special

switching, timing, PLC functions, and GFCI operation – contact our Sales Department.

11

Notes: 1. Models KBVF-27, 29: if a non-isolated signal is used, or if using 0 to ±2.5 thru 0 to ±25 Volts DC or 4 – 20 mA DC signal input, install the
SIVFR Signal Isolator (Part No. 9597). Models KBVF-45, 48: contain built-in signal isolation. 2. Allows the motor to operate up to two times the rated
RPM. Constant motor horsepower will result when operating the drive in the “X2” mode above the motor rated frequency. 3. Dependent on motor per-
formance. 4. Do not operate the drive outside the specified AC line input voltage operating range. 5. Models KBVF-45, 48 only.

Description

Specification

Factory

Setting

208/230 Volt AC Line Input Voltage Operating Range (Volts AC)

208 (–15%) / 230 (+15%)

400/460 Volt AC Line Input Voltage Operating Range (Volts AC)

380 (–15%) – 460 (+15%)

Maximum Load (% Current Overload for 2 Minutes)

150

Carrier, Switching Frequency (kHz)

16, 8

Signal Following Input Voltage Range

1

(Volts DC)

KBVF-27, 29

0 – 5

KBVF-45, 48

0 to ±2.5 thru 0 to ±25

0 to ±5

Signal Following Input Current Range

1

(mA DC)

4 – 20

Output Frequency Resolution (Bits, Hz)

10, .06

Minimum Speed Trimpot (MIN) Range (% Frequency Setting)

0 – 40

0

Maximum Speed Trimpot (MAX) Range (% Frequency Setting)

70 – 110

100

Acceleration Trimpot (ACC) and Deceleration Trimpot (DEC/B) Range (Seconds)

.3 – 20

1.5

Boost Trimpot (DEC/B) Range (50 Hz Only) (Volts/Hz)

0 – 30

5

Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)

0 – 3

1.5

Current Limit Trimpot (CL) Range (Amps AC)

KBVF-27

4.0 – 12.5

10.7

KBVF-29

5.5 – 17.0

14.4

KBVF-45

3.0 – 8.5

7.4

KBVF-48

5.0 – 15.5

13.3

Motor Frequency Setting (Hz) (Jumper J1)

50, 60

60

Output Frequency Multiplier (X1, X2) (Jumper J2)

2

1, 2

1

Minimum Operating Frequency at Motor (Hz)

1

Speed Range (Ratio)

60:1

Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)

3

2.5

Overload Protector Trip Time for Stalled Motor (Seconds)

6

AC Line Input Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line (±5%) (Volts AC)

4

151 – 282

AC Line Input Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line (±5%) (Volts AC)

4

302 – 567

Run/Fault Relay Output Contacts Rating

5

(Amps at 30 Volts DC, 125 Volts AC, 250 Volts DC)

1, 0.5, 0.25

Operating Temperature Range (°C / °F)

0 – 45 / 32 – 113

TABLE 1 – GENERAL PERFORMANCE SPECIFICATIONS

TABLE 2 – ELECTRICAL RATINGS

Model

Part

No.

AC Line Input

Drive Output

Fuse or

Circuit

Breaker

Rating

(Amps)

Net Wt.

Volts AC

(50/60 Hz)

Phase

(φ)

Maximum

Current

(Amps AC)

Voltage

Range

(Nominal)
(Volts AC)

Maximum

Continuous

Load Current

(RMS Amps/Phase)

Maximum

Horsepower

(HP (kW))

lbs

kg

KBVF-27

9591

208/230

1

17.0

0 – 230

6.7

2 (1.5)

20

4.1

1.9

3

8.0

10

KBVF-29

1

9593

208/230

3

10.8

0 – 230

9.0

3 (2.25)

15

4.6

2.1

KBVF-45

2

9590

400/460

3

5.3

0 – 400/460

4.6

3 (2.25)

10

4.1

1.9

KBVF-48

1, 2

9592

400/460

3

9.6

0 – 400/460

8.3

5 (3.75)

15

4.6

2.1

Notes: 1. Models KBVF-29, 48 contain built-in cooling fan. 2. Models KBVF-45, 48 are rated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460
Volts AC for 60 Hz motor operation.

*All models contain a Terminal Block for AC line and motor wiring. The Signal Isolator and Run/Fault Relay is standard on Models KBVF-45, 48
and optional on Models KBVF-27, 29.

This manual is related to the following products: