KB Electronics KBVF-48 User Manual
Page 11
• DIVF – Modbus Communication Module (Part No. 9568) – Allows the drive to communicate with
PLCs, PCs, and HMIs with Modbus RTU protocol utilizing a serial communication cable. If a USB
communication cable is required, purchase Part No. 19008.
• Custom Software – All models can be factory programmed for applications which require special
switching, timing, PLC functions, and GFCI operation – contact our Sales Department.
11
Notes: 1. Models KBVF-27, 29: if a non-isolated signal is used, or if using 0 to ±2.5 thru 0 to ±25 Volts DC or 4 – 20 mA DC signal input, install the
SIVFR Signal Isolator (Part No. 9597). Models KBVF-45, 48: contain built-in signal isolation. 2. Allows the motor to operate up to two times the rated
RPM. Constant motor horsepower will result when operating the drive in the “X2” mode above the motor rated frequency. 3. Dependent on motor per-
formance. 4. Do not operate the drive outside the specified AC line input voltage operating range. 5. Models KBVF-45, 48 only.
Description
Specification
Factory
Setting
208/230 Volt AC Line Input Voltage Operating Range (Volts AC)
208 (–15%) / 230 (+15%)
—
400/460 Volt AC Line Input Voltage Operating Range (Volts AC)
380 (–15%) – 460 (+15%)
—
Maximum Load (% Current Overload for 2 Minutes)
150
—
Carrier, Switching Frequency (kHz)
16, 8
—
Signal Following Input Voltage Range
1
(Volts DC)
KBVF-27, 29
0 – 5
—
KBVF-45, 48
0 to ±2.5 thru 0 to ±25
0 to ±5
Signal Following Input Current Range
1
(mA DC)
4 – 20
—
Output Frequency Resolution (Bits, Hz)
10, .06
—
Minimum Speed Trimpot (MIN) Range (% Frequency Setting)
0 – 40
0
Maximum Speed Trimpot (MAX) Range (% Frequency Setting)
70 – 110
100
Acceleration Trimpot (ACC) and Deceleration Trimpot (DEC/B) Range (Seconds)
.3 – 20
1.5
Boost Trimpot (DEC/B) Range (50 Hz Only) (Volts/Hz)
0 – 30
5
Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)
0 – 3
1.5
Current Limit Trimpot (CL) Range (Amps AC)
KBVF-27
4.0 – 12.5
10.7
KBVF-29
5.5 – 17.0
14.4
KBVF-45
3.0 – 8.5
7.4
KBVF-48
5.0 – 15.5
13.3
Motor Frequency Setting (Hz) (Jumper J1)
50, 60
60
Output Frequency Multiplier (X1, X2) (Jumper J2)
2
1, 2
1
Minimum Operating Frequency at Motor (Hz)
1
—
Speed Range (Ratio)
60:1
—
Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)
3
2.5
—
Overload Protector Trip Time for Stalled Motor (Seconds)
6
—
AC Line Input Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line (±5%) (Volts AC)
4
151 – 282
—
AC Line Input Undervoltage/Overvoltage Trip Points for 400/460 Volt AC Line (±5%) (Volts AC)
4
302 – 567
—
Run/Fault Relay Output Contacts Rating
5
(Amps at 30 Volts DC, 125 Volts AC, 250 Volts DC)
1, 0.5, 0.25
—
Operating Temperature Range (°C / °F)
0 – 45 / 32 – 113
—
TABLE 1 – GENERAL PERFORMANCE SPECIFICATIONS
TABLE 2 – ELECTRICAL RATINGS
Model
Part
No.
AC Line Input
Drive Output
Fuse or
Circuit
Breaker
Rating
(Amps)
Net Wt.
Volts AC
(50/60 Hz)
Phase
(φ)
Maximum
Current
(Amps AC)
Voltage
Range
(Nominal)
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW))
lbs
kg
KBVF-27
9591
208/230
1
17.0
0 – 230
6.7
2 (1.5)
20
4.1
1.9
3
8.0
10
KBVF-29
1
9593
208/230
3
10.8
0 – 230
9.0
3 (2.25)
15
4.6
2.1
KBVF-45
2
9590
400/460
3
5.3
0 – 400/460
4.6
3 (2.25)
10
4.1
1.9
KBVF-48
1, 2
9592
400/460
3
9.6
0 – 400/460
8.3
5 (3.75)
15
4.6
2.1
Notes: 1. Models KBVF-29, 48 contain built-in cooling fan. 2. Models KBVF-45, 48 are rated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460
Volts AC for 60 Hz motor operation.
*All models contain a Terminal Block for AC line and motor wiring. The Signal Isolator and Run/Fault Relay is standard on Models KBVF-45, 48
and optional on Models KBVF-27, 29.