beautypg.com

IAI America IX-NNW3515 User Manual

Page 66

background image

60

7. Specifi

cations

Item

Specifications

Ambient temperature/humidity

Temperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)

Operating
environment

Altitude

m

1,000 or less

B

d

e

s

i

o

N

71

Robot weight

kg

21

Air purge pressure (*11)

0.6 MPa max.

Controller

Power supply

230 V

50/60 Hz

5 A

Allowable supply voltage fluctuation

%

10

Overvoltage category (IEC60664-1)

Category III

Pollution degree (IEC60664-1)

Pollution degree 3

*1

To move the robot horizontally at high speed, perform teaching so that the vertical axis stays as close to the top position as
possible. (Fig. 1)
To operate the robot with its vertical axis at the bottom position, the speed and acceleration must be reduced as appropriate.
(Fig. 2)

*2

Assuming PTP instruction operation.

*3

Measured at a constant ambient temperature of 20 C.

*4

Measured when the robot is operated at the maximum speed, carrying a load of 2 kg.

*5

A force of up to three times the dynamic push-in thrust may be applied at any given moment.

*6

The static thrust refers to thrust generated within the robot’ s range of operation based on PAPR instruction.

*7

The permissible moment of inertia converted to a value at the rotational center of axis 4. The offset from the rotational center of
axis 4 to the tool’ s center of gravity is assumed to be 40 mm or less. (Fig. 3)
If the tool’ s center of gravity is further away from the rota

tional center of axis 4, the speed and acceleration must be reduced

as appropriate.

*8

If the tool exceeds the permissible diameter, it will contact the robot inside the robot’ s range of movement. (Fig. 4)

*9

Pins 1 to 15 of the connector can be used. Pin 16 is connected to the shielded cable and cannot be used for signal lines.

*10

To enable the alarm LED indicator, the user must provide a circuit that supplies 24 VDC to the LED terminal in the user
connector in response to the controller I/O output signal, etc.

*11

A recommended air purge pressure is 0.3 MPa or above (maximum pressure: 0.6 MPa). Increase the pressure to a range of
0.3 to 0.6 MPa until immediately before the bellows starts to inflate, and adjust the flow rate using the speed controller.
As a purge medium, use clean, dry air free from compressor oil or other contaminants, conforming to an air filtration rating of
10 m or below.

Reference design standards: Annex I to Machine Directives, EN292-1, EN292-2, EN1050, EN60204-1, EN775

Top position

Tool

Tool

Tool

Tool

Bottom
position

Center of
rotational axis

Center of
rotational axis

Tool’ s center
of gravity

(Fig. 1)

(Fig. 2)

(Fig. 3)

(Fig. 4)

40

80

Brake power source for main unit

W

24V DC ±10%

20W