10. TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

SOLUTION

No heat/cooling in

Zone thermostat(s)

Set COOL/OFF/HEAT switch on the

house

thermostat(s) to the proper setting.

Faulty heating/cooling equipment

Troubleshoot equipment according to
manufacturer’s instructions.

Faulty thermostat

Troubleshoot equipment according to
manufacturer’s instructions.
Replace if necessary.

Faulty zone control panel

Follow instructions outlined in Setup
and Test. Replace if necessary.

Improper remote switch selector

Ensure the switch is set to a mode of

setting (if installed)

operation which allows the requested
call to be serviced.

No heat/cooling in

Balancing damper closed

Check all balancing dampers in the

zone

same duct as the motorized zone
damper; closed balancing dampers
should be readjusted.

Zone registers closed

Check all zone registers; closed
registers should be readjusted.

Faulty thermostat

Troubleshoot thermostat according
to manufacturer’s instructions.
Replace if necessary.

Faulty zone control panel

Follow instructions outlined in Setup
and Test. Replace if necessary.