beautypg.com

Robertshaw 8601-1 User Manual

Page 6

background image

6

To Test Thermostat

WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS

VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL
DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.

CAUTION: DO NOT SWITCH SYSTEM TO A/C OR LEAVE IN A/C MODE IF

THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN
DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PER-
SONAL INJURY.

1. Place the HEAT-OFF-A/C switch into the A/C

position. The

will be displayed.

2. Press the

button until the temperature

setting is at least 3 degrees below the room
temperature. The air conditioning system
should turn on within a few seconds.

NOTE: ONCE THE THERMOSTAT TURNS OFF WHEN IN THE A/C MODE,

A BUILT IN 5-MINUTE DELAY PREVENTS THE SYSTEM FROM
TURNING ON AGAIN. THIS PROTECTS THE COMPRESSOR. NO
ADDITIONAL TIME DELAY RELAY IS REQUIRED. TO OVERRIDE THE
5-MINUTE DELAY FOR INSTALLATION, PRESS THE RESET BUTTON.

3. Put the HEAT-OFF-A/C switch into the OFF

position. The air conditioning system should
turn off.

4. Put the HEAT-OFF-A/C switch into the HEAT

position. The will be displayed.

5. Press the

button until the temperature

setting is at least 3 degrees above room
temperature. The heating system should turn on. The fan may
not turn on immediately, depending on the fan delay built into
the furnace.

NOTE: If HP is selected, the heat will not come on until the 5 minute

short cycle protection has expired.

6. Put the HEAT-OFF-A/C switch into the OFF

position. The heating system should turn off.
The fan may continue to run for a short
period of time.

7. Put the AUTO

ON switch into the ON

position. The blower fan should turn on.
The display will show a

.

8. Put the AUTO

ON switch into the AUTO

position. The blower fan should turn off.

a/c

off

heat

a/c

off

heat

a/c

off

heat

a/c

off

heat

on

auto

on

auto

!

110-1165 6/8/05 11:51 AM Page 6