Section VI - Clamp Ring Replacement and Reassembly

1. Inspect the clamp ring. If clamp ring requires replacement, it is recommended to remove the plastic foot (item 15)

first. NOTE: 100/112 frame B5 adapters do not use the foot. See figures 32 and 33. Remove the four (4) M6 bolts

(items 28 and 28A).

Figure 32

Figure 33

2. Remove the five (5) M8 bolts, lock washers and flat washers (items 34, 33, and 32) from the clamp ring (item

12B). See figure 34. Remove the clamp ring from the motor adapter. There is a snug fit between the clamp ring

and motor adapter due to the vapor protection o-ring (item 12C). Carefully pull the two parts apart. See figure 35.

Figure 34

Figure 35

3. Inspect the motor adapter o-ring (item 12C). Replace if damaged. If it is re-

usable, lubricate it with a chemically compatible lubricant. See figure 36.

Figure 36

4. Install the new clamp ring. Place the clamp ring on a flat surface. See figure

37. Align the bolt holes (five motor adapter and two foot bolt holes) on the
clamp ring with the bolt holes on the motor adapter. Push the motor adapter

straight down onto the clamp ring to seat the o-ring. See figure 38. Install five

M8 bolts, lock washers and flat washers (items 34, 33 and 32) and tighten in a

star pattern to 130 in-lbs. (14.7 N-m). See figure 39.

Figure 37

Figure 38

Figure 39