Section 5: Service & Maintenance

5.1. RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE

5.1.1. Performed

every month

• Lift up the scale, checking all attached wires, wear points, and that all bolts are

securely tightened.

• Check all clearances around the scale for any obstructions or interference with

the free movement of the platform.

• Check deck surface for any signs of damage or deterioration. Fix as needed, or

move the scale’s position.

• Lower the scale onto its permanent position.
• Check all check bolt clearances, both with and without

a concentrated load over each section, one at a time.

• Check load cells for a level condition.

5.1.2. Performed every

six (6) months

• Lift up the scale, checking all attached wires, wear points, and that all bolts are

securely tightened.

• Check cups and "O" rings for any damage.
• Inspect and adjust all Check Bolts, using anti-seize on the threads.
• Ensure that the system is has proper ground connections
• Remove the J-box covers and inspect for water seepage.
• Check that all terminal screws and contacts are secure.
• Check that all jumpers are in place.
• Dress all wires, being certain they are completely off the

ground.

• Check that waterproof gland nuts are tight.
• Reinstall the box cover, fasten the latches, and check the seal.
• Check all clearances around the scale for any obstructions or interference with

the free movement of the platform.

• Check all bumper bolt clearances, both with and without a concentrated load over

each section, one at a time.