Acer Management Modules provide the following additional beep
codes.

Error Beep Codes Provided by Acer® Management Modules

Beep Code

Reason for the beeps and action to take

1

Control panel CMOS clear has been initiated.

1-5-1-1

Processor failure. Reseat or replace the failed processor.

1-5-2-1

No processor is installed or the CPU 1 socket is empty.
Reseat or replace the failed processor.

1-5-2-3

Processor configuration error or CPU 1 socket is empty.
Reseat or replace the failed processor. In a two-processor
system, make sure the processors are identical.

1-5-2-4

Front-side bus selects configuration error.

1-5-4-2

DC power unexpectedly lost.

1-5-4-3

Chipset control failure.

1-5-4-4

Power control failure.