beautypg.com

1 overview, 2 typical applications, Introduction………………………………………………………………1 – Teledyne 2000XTC - Thermal conductivity analyzer User Manual

Page 11: Introduction

background image

Thermal Conductivity Transmitter

Introduction

Introduction

1.1 Overview

The Teledyne Analytical Instruments 2000 XTC Thermal Conductivity

Transmitter is an instrument designed to analyze the gas concentration of a
binary gas mixture. This manual covers the CENELEC/ATEX approved
model 2000 XTC Thermal Conductivity Transmitter. These units are rated as
intrinsically safe and may be used in Class I, Group A, B, C, D, Div. 1 (North
America) and EEx ib IIC T3 (IEC/Europe) hazardous environments.

1.2 Typical Applications

The 2000 XTC Thermal Conductivity Transmitter is versatile. It is

capable of measuring the gas concentration of a species in a binary or
pseudo-binary mixture of gases over a concentration range. The specific
species and gas mixture as well as the analysis range employed is fixed
at the factory for your specific application. Typical applications for this
transmitter include:

Determining the gas concentration of a binary gas, for
instance, Ar or N

2

in air

Analyzing the methane (CH

4

) concentration in natural gas

(80-100% CH

4

) sample

Analysis of H

2

in various backgrounds

CO

2

safety monitoring

Specific gas mixer and process control applications

Semiconductor manufacturing

Petrochemical process control

Quality assurance

Typical instrument ranges for this instrument include:

H

2

in N

2

(or air)

0-5%, 0-8%, 0-10%, 0-20%, 0-100%

Teledyne

Analytical

Instruments

1