beautypg.com

Le maintenance – Fulton Edge ICX or FB-F Vertical Tubeless Boilers (Steam), Gas Fired User Manual

Page 24

background image

18-G 1/01

Troubleshooting

a. The following troubleshooting

guide will assist in the diagnosis and

the correction of minor field prob-

lems. It contains instruction and

information necessary to locate and

isolate possible troubles which

occur during normal operation. It

should be used in conjunction with

the unit wiring diagram and the

component literature provided in

Section 7 of this manual.

b. The following lists cover the most

common troubles that may occur on

the Fulton gas fired boilers. Refer

to left hand column of the chart to

locate the problem. Determine

which cause, listed in the center col-

umn, that represents the problem by

performing the corrective action as

listed in the right hand column titled

“REMEDY”.

Troubleshooting Gas-Fired Boilers

Problem

Cause Remedy

Ignition Failure

1. Power Supply

Check fuse or circuit breaker. Reset or

replace, as necessary.

2. Ignition Electrodes

Check electrodes for carbon buildup and clean if necessary.
Check for proper adjustments. Readjust if necessary.

Check for cracks in porcelain. If found, replace.

3. Transformer

Check voltage between transformer leads at terminal block

to be sure transformer is being powered.

4. Flame Safeguard

Check voltage between ignition terminal and neutral.

Control

Check must be made before control locks out on safety.

If no power, replace control.

5. Faulty Air Switch

Check for bad air switch by jumpering the two air switch

leads at the terminal block. If the boiler starts and runs with

these terminals jumpered, the air switch should be

replaced.

6. Gas Valve Sticking

Check for dirt in valve or orifice and clean if necessary.

(Pilot)

Check for faulty actuator or valve and replace if necessary.

7. Gas Supply

Check for gas pressure and for intermittent supply

problems. See test fire sheet for last elbow.

8. Loose wire connection

Check connections to all components.

Flame Failure

1. Power Supply

Check fuse or circuit breaker. Reset or replace, as

necessary.

2. Gas Supply

Check for gas pressure and for intermittent supply

problems.

3. Ignition Electrodes

Check electrodes for carbon buildup and clean if necessary.

Check for proper adjustment. Readjust if necessary.

Check for cracks in porcelain; if found, replace.

4. Primary Air Adjustment

Check air adjustment. Air may be blowing flame away

from burner head.

LE Maintenance