Prior to installation

2. Insert the one-way flap into the bearing

apertures on the air-pipe connector.

If the exhaust air is going to be

discharged into the open, a telescopic

wall box should be fitted into the outside

wall.
For optimum extractor hood efficiency:
❑ Short, smooth air exhaust pipe.
❑ As few bends in the pipe as possible.
❑ Diameter of pipe to be as large as

possible (ideal is l 120 mm ) and no

tight bends in pipe.
If long, rough exhaust-air pipes,

many pipe bends or smaller pipe

diameters are used, the air extraction

rate will no longer be at an optimum

level and there will be an increase in

noise.

❑ Round pipes:

We recommend

Internal diameter at least. 120 mm.

❑ Flact ducts must have an internal

cross-section that equates to that of

round pipes with a 100/120 mm internal

diameter

There should be no sharp bends.

l 100 mm approx.

0

78 cm

2

l 120 mm approx. 113 cm

2

If pipes have different diameters:
❑ Insert sealing strip.
❑ For exhaust-air mode, ensure that

there is an adequate supply of fresh air.

Exhaust air flows upwards:

❑ Cut a hole in the top of the wall cupbo-

ard, including a groove for the mains

cable.

– Template

O

I

lis enclosed –.

For operating in exhaust-air mode, a

one-way flap should be mounted inside the

extractor hood unless there is already one

fitted in the outlet duct or wall ventilation

box.

If no one-way flap was enclosed with the

hood, it can be obtained from a specialist

retailer (see section on optional accessories

in the user instructions).
Installing the one-way flap:
1. Cut out the protective grid in the air-pipe

connector.

21

32

600

170

133

287

313

195

250

mind. 30

115

80

185

120

512

243

269

90

250

32

280

598

280-443

Connecting the l 120 mm

exhaust-air pipe:

❑ Cut out the protective grid in the air

outlet.

Circulating-air mode

❑ With activated carbon filter if exhaust-air

mode is not possible.

The complete

installation set can

be obtained from

specialist outlets.

The corresponding

accessory numbers

can be found at the

end of these opera-

ting instructions.

O

100

120

Exhaust flows straight out at the

back:

– inside the wall cupboard –.
❑ Cut a hole in the rear panel of the wall

cupboard, including a groove for the

mains cable.

Connecting the l 100 mm

exhaust-air pipe:

❑ Cut out the protective grid in the air

outlet.

❑ Attach the reducing connector (enclosed

or can be obtained from specialist

retailers) to the air outlet.

Electrical connection

This is what you have to do:
1.Connect the green and yellow (Earth)

wire to the terminal in the plug marked

‘E’ or with the symbol (

), or

coloured green or green and yellow.

2.Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or

coloured black.

3.Connect the brown (Live) wire to the

terminal marked ‘L’, or coloured red.

The extractor hood may only be

connected to an earthed socket that has

been installed according to the relevant

regulations. If possible, site the earthed

socket directly above the wall cupboard or

in its immediate vicinity.

Electrical data:

Are to be found on the name plate inside

the appliance after removal of the filter

frame.

Before undertaking any repairs,

always disconnect the extractor hood from

the electricity supply.
Length of the connecting cable: 1.30 m.
If it is necessary to wire the extractor

hood directly into the mains:
The extractor hood should only be

connected to the electricity supply by a

properly qualified electrician.
A separator must be installed in the

household circuit. A suitable separator is a

switch that has a contact gap of more than

3 mm and interrupts all poles. Such

devices include circuit breakers and con-

tactors.
This extractor hood corresponds to EC

regulations concerning RF interference

suppression.