beautypg.com

Detroit Radiant Products Company SV Series User Manual

Page 5

background image

SV

Series

5

Model Number

Mounting

Angle*

Side

Top

Below

Front

Behind

SV (20, 30, 40) - 50, 60 [N, P]

9

9

6

47

45°

39

8

10

47

with 1 side shield

29

8

6

47

with 2 side shields

9

9

6

47

20 ft. from burner

7

7

6

30

SV (20, 30, 40) - 75 [N, P]

9

9

6

60

45°

39

8

10

60

with 1 side shield

29

8

6

60

with 2 side shields

9

9

6

60

20 ft. from burner

7

7

6

30

SV (30, 40, 50) - 100 [N, P]

14

14

6

66

45°

39

8

10

66

with 1 side shield

29

8

6

66

with 2 side shields

16

16

6

66

20 ft. from burner

7

7

6

30

SV (30, 40, 50) - 125 [N, P]

20

20

6

76

45°

58

8

10

76

with 1 side shield

42

8

6

76

with 2 side shields

20

20

6

76

20 ft. from burner

7

7

6

30

SV (40, 50, 60) - 150 [N, P]

24

24

6

81

45°

58

8

10

81

with 1 side shield

42

8

6

81

with 2 side shields

23

23

6

81

20 ft. from burner

11

11

6

44

SV (40, 50, 60, 70) - 175 [N, P]

34

34

6

92

45°

63

8

10

92

with 1 side shield

50

8

6

92

with 2 side shields

30

30

6

92

20 ft. from burner

11

11

6

44

SV (50, 60, 70, 80) - 200 [N, P]

41

41

6

94

45°

63

8

10

94

with 1 side shield

54

8

6

94

with 2 side shields

30

30

6

94

20 ft. from burner

11

11

6

44

Chart 1.1 •

Clearance to Combustibles in Inches (see Figure 1.1 for Mounting Angles)

1.0

Safety

Clearance to Combustibles

The stated clearance to combustibles represents a surface temperature of 90°F (32°C) above room
temperature. Building materials with a low heat tolerance (such as plastics, vinyl siding, canvas,
tri-ply, etc.) may be subject to degradation at lower temperatures. It is the installer’s responsibility to
assure that adjacent materials are protected from degradation.

Figure 1.1

Mounting Angles

45° Mounting Angle

0° Mounting Angle

with 1 Side Shield

(P/N: SSE)

0° Mounting Angle

with 2 Side Shields

(P/N: SSE)

Front

Behind

Below

Top

Front

Behind

Below

Top

Side

Side

Below

Top

0° Mounting Angle

Side

Side

Below

Top

5

*