0 safety, Sa mp le sa mp le, Sample – Detroit Radiant Products Company SV Series User Manual
Page 3: Safety labels and their locations, F/n: llac air metering orifice, Sv series, 0 safety • safety labels and locations

SV-40-125N
Data on this label is for the model shown on this label. If your heater has been converted,
this information is not accurate. Please contact the factory for assistance.
BURNER COMPONENTS:
For parts replacement information, contact factory at 586-756-0950 or visit www.drp-co.com/parts.
Serial No.: 0804XXXXXXXXXX 0001
Gas Valve:
Circuit Board:
Wire Harness:
N.O. Switch:
N.O. VL Orifice:
N.C. Switch:
N.C. VL Orifice:
Diff Switch:
Diff VL Orifice:
Igniter:
Burner:
16” Tube:
Ind. Lights:
Diag. Light:
Term. Block:
Transformer:
Fan:
Alt. Fan:
Alt. Fan Usage:
Relay:
Filter:
24 Volt In:
120 Volt In:
Gas In:
Extra VL Orifice:
Production Code:
Version:
Stock:
Add-On:
Internal Use Only:
HEATER
TYPE:
Electric:
Tag:
Special 1:
Special 2:
Gas:
Air:
C1
C1
C2 C3
None
N/A
SV-125
36G54-224
Triton - 2465H
None
None
N/A
None
None
IS22016051F5169
Black(+ / -)
24V Norton
High
4” 24 Mini
Yellow - 24V
(Specify TP-#’s)
1240A
1251
None
N/A
N/A
264E
1250
201B
1280
828
None
10 - Spade
None
PB - (7-10)
None
Pack 1 p/ burner
None
None
2T - plug
trans Box
7/8” FC Flare
Yellow
329
826
1215
N/A
N/A
N/A
832
1266
83
10
2 1/4”
TP-204#
TP-114#
10
2 1/4”
LLWT020
None
9
2 1/4”
Pump ID
24V - ID
Orifice Type:
®
DETROIT RADIANT PRODUCTS COMPANY
21400 HOOVER ROAD - WARREN, MI
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR (Non-Residential) INSTALLATION ONLY.
Class IIIA Permanent Label
(586) 756-0950
- www.drp-co.com
Volts AC:
AMPS - Starting:
AMPS - Running:
Combustion Chamber:
24V - 60Hz
3.0
2.0
4” Black Coated Aluminized
DESIGN COMPLIES WITH:
ANSI Z83.20b-2004-GAS FIRED LOW INTENSITY INFRA-RED HTR.
Manifold Pressure:
Maximum Inlet Pressure:
Minimum Inlet Pressure:
3.5 in.
14 in.
5.5 in.
W.C.P.
W.C.P.
W.C.P.
Serial No.: 0807XXXXXXXXXX 0001
MODEL NO.
SV- 40 - 125N
Heater Type
Minimum Mounting Angle:
Maximum Mounting Angle:
C1
0
45
DEGREES
DEGREES
INPUT BTU/H
125,000
FOR USE WITH
Natural Gas
1.0
Safety
SA
MP
LE
SA
MP
LE
SV
Air Metering Orifice
DO NOT REMOVE
TP-114
TP-3014
1 - 1/2"
F/N: LLAC
Air Metering Orifice
SAMPLE
SV
Series
3
Safety Labels and Their Locations
Read and understand all safety information and warnings in this insert manual and the
Tube Heater General Manual before installation, operation and maintenance of the
radiant tube heater system.
Back Panel
Top Panel
Bottom Panel
Rating Plate
F/N: LLTB018 (Natural Gas)
F/N: LLTB019 (LP Gas)
F/N: LLTCL001
Clearance to Combustibles Label.
F/N: LLLOGO1
Burner Control Box
Component Label
(located under the top panel)
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.
1.0
Safety
•
Safety Labels and Locations