beautypg.com

Meriam M2110F SMART FLOW GAUGE User Manual

Page 32

background image

32

14.2 CURRENT LOOP MODEL WIRING

14.2.1 Current Loop Model Interface Connections

The Current Loop Model connections are made through the supplied interface cable. The cable is connected to an
eight (8) pin circular receptacle on the back of the unit. These connections will be defined by wire color coding of
the cable.

Pin #

Wire
Color

Description

Function

Notes

1

BLACK

0 VDC IN

Gauge Power Supply Common

0 VDC Input

2

WHITE

-LOOP

4-20 mA Analog Return

(+) mA output to receiver

3

RED

+LOOP

4-20 mA Loop Power Input

4

GREEN

+24VDC IN

Gauge Power Supply Input

+ 24 VDC Input Nominal

5

NOT USED

6

BROWN

RS232 Common

RS232 interface common connection

0 VDC

7

BLUE

RS232 Rx

RS232 receive input connection

For Serial Menu

8

ORANGE

RS232 Tx

RS232 transmit output connection

For Serial Menu


Note: See Appendix for wiring specifics.



























Note: R = Receiving Device

24 VDC/ 50 mA
Power Supply

+

-

Gauge & Loop Power

R

2110F
4

3


2

1

3 WIRE SINKING

24 VDC/ 50 mA
Power Supply

+

-

Gauge & Loop Power

R

2110F
4

3


2

1

4 WIRE SOURCING

LOOP
+ Power Supply
24 VDC

20mA

-

R

4



3

2

2110F

FLOW
GAUGE

1

+




GAUGE
Power Supply
24 VDC/ 30 mA


-

4 WIRE FLOATING