Magnum Venus Plastech PATRIOT SSB Commissioning and instruction User Manual
Page 25
SSB_Auto Instructions Issue 05
Page25
Resin Gel Alarm – RGA
The RGA unit is set to operate only when injection takes place. On injection start both the
green light and yellow light illuminate.
If injection is either stopped or the machine stops pumping (stalled) for more than 60 -120
seconds the Top green light will change colour to Red flashing mode and an audible alarm will
sound.
If injection is restarted then the Red light changes back to Green and the alarm warning stops.
At the end of injection when the counter or the operator stops the injection and proceeds to
flush the machine head the Red light will continue to flash for 30 seconds (without the audible
warning) and the RGA unit will then revert to sleep mode.
If the operator switches off the flush command earlier than 30 seconds the audible warning will
start again with the red light still on demanding that a full 30 seconds of flush and head mixer
air dry out is commanded.
Low battery.
The internal 9 vdc battery is accessed by sliding out the front battery draw. Under normal use
the standard PP3 9vdc battery should last for more than two weeks. If the battery has
Start – Green
Alarm
- Red
flashing
Power on
Injecting
- Yellow
Battery low
-Yellow flashing
9 VDC
battery (PP3
type)