0 maintenance – Magnum Venus Plastech PATRIOT SSB Commissioning and instruction User Manual
Page 11
SSB_Auto Instructions Issue 05
Page11
The catalyst inlet filter located within the catalyst bottle should be removed and cleaned in
solvent and water at least every 4 months.
The Catalyst bottle internals must remain clean. If catalyst appears to be discoloured or any
form of sediment is observed within the catalyst bottle remove and clean as necessary and dry
out before replacing with fresh catalyst and placing back into service. Use only water through
the catalyst system if cleaning is necessary. Do not use or pump solvent based cleaners in the
catalyst fluid section
7.3 Solvent Pump system. The Solvent tank requires no routine maintenance however if dirt
particles as sediment accumulate within solvent tank base remove and clean and refill with
fresh solvent.
The remaining solvent system should only be routinely maintained by weekly checks to locate
any leaks or damaged pipes which should be repaired immediately
See separate sheet on internal part maintenance in section 12.0
7.4 Mixing head assembly. The Resin mix pressure sensor (Mould Pressure Guard -MPG) has
an internal diaphragm which should be renewed periodically. A renewal rate after every 10,000
Kg mix usage is recommended. See sections 11.0 and 11.1
8.0 Maintenance
Important Safety Note All maintenance work on the machine must be carried out with the air
supply to the machine disconnected and due caution must be observed when opening all fluid
and pneumatic connections by using personal protection against possible internal residue
pressures.
The following sections describe seal and internal fluid section maintenance procedures
accompanied by assembly and parts drawings.