To determine the Glass Rate Meter calibration number for any glass yield
not given in charts C and D calculate the calibration number as the
example below.

VRC-2000-XXX, Pro Chopper and 4 Strand Chopper assemblies (70020-X)

Example: Yield 205 yds/lbs

Rotor circumference:

VRC-2000-XXX, Pro Chopper and 4 Strand choppers (70020-X) = 3.7699 in.

6 Strand Chopper Assembly (70010-1) = 5.4035 in.


1. Multiply yield number by 36 (inches in a yard).

205 yds

36 in

1 lbs

1 yd


2. Divide the circumference of the chopper rotor in inches by the glass

yield in inches.

3.7699 in

7380 in

1 rev

1 lb


3. Multiply the result of step 2 by 60 (the seconds in one minute).

.0005108 lbs

60 sec

1 rev

1 min


4. Multiply the result of step 3 by the number of strands.

.03065 x 2 strands = .06130 calibration number for 2 strands















x

= 7380 in / lb

x

= .00005108 lbs / rev

x

= .03065 calibration number for 1 strand