Part 2, Resin total meter programming – Magnum Venus Plastech CB-6000-RGT Imperial units PROGRAMMING User Manual
Page 12

11
Part 2
Resin Total Meter programming:
The Resin Total Meter is pre-programmed by MVP at the factory. All values
that appear on the display must remain as set by MVP for the unit to
function as a totalizer. There are two exceptions, at step 6 where the
decimal point is placed and step 7 where the calibration number for resin
specific gravity is entered.
All programming is accomplished from the front of the Resin Total Meter.
There are a series of switches at the rear of the meter that are preset at the
factory and should not be changed. The exceptions are; the voltage switch
in the upper left corner can be changed between 120 VAC and 220 VAC.
The other is the switch on the far right of the group of switches located in
the terminal strip. Pushing this switch up to the ON position will lock in a
program so it cannot be changed until the switch is turned off, the down
position as it comes from the factory.
The following is the programming sequence;
Step 1) Turn the front panel power switch off.
Step 2) Connect power, 115/230 VAC, 50/60 Hz, 6 VA, to the unit.
NOTE: The unit is set for voltage specified when order was placed.
To change voltage remove back panel of meter and position slide
switch in upper left corner to desired voltage.
Turn on front panel power switch. The initial totalizer display will look like this:
Step 3) Push the RUN/PROGRAM button and the display will change to this: