(Figure 2. Inlet Panel)


Outlet Panel
RESIN HEATER
RESIN
RESIN RETURN
HARDENER HEATER
HARDENER
HARDENER RETURN
AIR SUPPLY
AIR SIGNAL RETURN
SOLVENT

(Figure 3. Outlet Panel)


Install Electrical Wire
DANGER: Only Qualified Electricians Should Install Electrical System!

Install electrical wire (220 single phase, 25 amp) through manifold panel at lower side of machine (see
Figure 4). If flammable materials are to be processed, explosion

–proof wiring must be used.


To install the unit hoses, perform the following steps:
Unpack all hoses and inspect for kinks or damage.
Install green pickup hoses and black recirculation hoses to INLET PANEL on left side of the right panel.
Install high-pressure relief hose to lower fitting at the same panel. Place hoses in correct material
containers.

Be extremely careful to match the proper recirculation hose with the correct pickup wand or material will be
contaminated. The high-pressure relief hose should be placed in a separate container.