Liquid Controls SP2900 User Manual
Page 6
D
ENT
B
D
8
1
7
ENT
STEP
4
SETTING
THE
RATEMETER
CLR
CLR
5
ENT
CLR
6
PRESS
DISPLAY
MENU FLASHES TO DEV TYP
RT
CNT
(RATE OR COUNT)
(SET UP RATEMETER)
K FACTOR FLASHES; THEN SHOWS
CURRENT K-FACTOR
0 FLASHES
1 7 . 8 FLASHES
(PRESS D FOR DECIMAL POINT)
K FACTOR IS DIVIDER. IT CONVERTS INPUT TO ENGINEERING UNITS.
(K FACTOR ENTERED)
WINDOW ##
WINDOW 00
(AS AN EXAMPLE)
WINDOW 05
(EXTENDS THE SAMPLING WINDOW TO 5 SECONDS)
(WINDOW ENTERED)
SIG FIG ##
SIG FIG 00
(AS AN EXAMPLE)
SIG FIG 06
(SIG FIG INDICATES HOW MANY MEANINGFUL DIGITS ARE SHOWN
TRAILING ZEROS ARE INSERTED IF NECESSARY)
(SIG FIG ENTERED)
WEIGHT #.#
WEIGHT 0.0
(AS AN EXAMPLE)
WEIGHT 9.9
WEIGHT IS AN AVERAGING FACTOR. HIGHER SETTINGS PROVIDE MORE AVERAGING, FOR A
MORE STABLE DISPLAY. DERIVED FROM:
(WEIGHT ENTERED)
LAST COUNT READING
MENU FLASHES TO DEV TYP
LOCKOUT
(LOCKOUT SELECTED)
CODE FLASHES; THEN SHOWS OLD CODE #.
0 FLASHES
(AS AN EXAMPLE)
1 1 1 1 FLASHES
(CODE ENTERED)
PR LCK
PR UNLK
(LOCKOUT OF
(LOCKOUT OF ALL FRONT
FRONT PANEL)
BUTTONS EXCEPT
PRESETS A, B AND CLR)
(LOCKOUT SELECTION ENTERED)
LAST COUNT READING
LOCK ON FLASHES
(APPROPRIATE PANEL CHANGES LOCKED OUT)
LOCK OFF FLASHES
(PANEL CHANGES ALLOWED)
ENT
4
D
ENT
CLR
1
1
1
1
ENT
ENT
1
1
1
1
1
1
1
1
(OLD DATA x "WEIGHT" + NEW DATA)
("WEIGHT" + 1)
ENT
9
9
STEP
5
SETTING
LOCKOUT
CODE
CLR